ws-x6408a-gbic eol. --- ----- ----- ----- ----- 1 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC View and Download Cisco Catalyst X6724 datasheet online. ws-x6408a-gbic eol

 
 --- ----- ----- ----- ----- 1 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC View and Download Cisco Catalyst X6724 datasheet onlinews-x6408a-gbic eol  NO FIX

Anantha Subramanian. thanks andy 1 2 Catalyst 6000 supervisor 2 (Active) WS-X6K-SUP2-2GE SAL0652AUD0 3 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL0548EYF2 4 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL061424MF 6 16 SFM-capable 16 port 1000mb GBIC WS-X6516A-GBIC SAL0810VS9M 9 0 SLB Application Processor Complex WS-X6066-SLB-APC SAD07390253 Hi guys, I'll be running a Cisco catalyst 6500 series, with the following Fiber Line cards, WS-X6708-10G + WS-X6408A-GBIC. GBICs) WS-X6516A-GBIC= Catalyst 6500 16-port GigE Mod, fabric-enabled (Req. WS-X6416-GBIC EOS: 01/15/06(PB 2970) C6500 16-port Gig-Eth Mod. Part number: WS-G5483 (1000Base-T GBIC) WS-X3500-XL GigaStack GBIC SFP Module This uses Cisco Gigastack connector and cable. WS-X6516A-GIBIC. CISCO CATALYST 6000 8-PORT GE ENHANCED GBIC. I need to buy the DFC3BXL in this case. in Austria: +43 720 775089. The goal is to increase number of GBIC ports using existing Supervisory Engine module. Using CEF you will get up to 30 Mpps per system, or you can install the dCEF upgrade to support 48 Mpps. By fail, I mean it goes into "other" state and all ports are listed as "errdisable. We've had the line card module in slot 4 fail multiple times over the last few months. The 8-port Gigabit Ethernet switching module (WS-X6408A-GBIC) provides eight switched, full-duplex Gigabit Ethernet ports that you can configure with any combination of 1000BASE-SX, LX/LH, and ZX. bin. Catalyst 6000 8-port GE, Enhanced QoS (Req. Transceiver Illustrations Transceiver Specification Tables GBIC † WS-X6408A-GBIC † WS-X6416-GBIC † WS-X6516-GBIC. Module 1: WS-X6K-SUP1A-2GE Module 2: Removed Module 3: WS-X6348 Module 4: WS-X6348 Module 5: WS-X6408A-GBIC Module 6: WS-X6408A-GBIC However, its not able to detect the switch module. The Coarse Wavelength Division Multiplexing (CWDM). This is how the configuration looks: 6506 with Supervisor Engine 1 <= WS-X6516A-GIBIC 6509 with Supervisor Engine 32 <= WS-X6408A-GIBIC Hello, I have a WS-C6509 chassis with the following modules: 2x WS-X6K-SUP1A-2GE; 3x WS-X6408A-GBIC; 1x WS-X6516A-GBIC; 1x WS-X6348-RJ-45 and WS-X6148-GE-TX. " We've also had the module in slot 5 fail twice with the same symptoms. • The ip tcp adjust-mss command is supported in crypto-connect and VRF. Cheers, Ross. CH-6509#show mod Mod Ports Card Type ModelX6408A-GBIC WS-X6416-GBIC WS-X6516-RJ-45 (voor 1000Base-T GBIC) Categorie 5, 5e, 6 UTP. 5 48 unknown FRU type (major = 0x6003, mino WS-X6748-GE-TX SAL08290NL3. . 3 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL0718CF0W 4 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL1114KYME 5 2 Route Switch Processor 720 (Active) RSP720-3CXL-GE SAL17299PHR 6 2 Route Switch Processor 720 (Hot) RSP720-3CXL-GE SAL17299PGC 9 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL1528JG4W. WS-X6408-GBIC WS-X6408A-GBIC WS-X6416-GBIC WS-X6516-GBIC WS-X6516A-GBIC WS-X6816-GBIC8 or 16 GBIC module slots RJ-45 (for 1000Base-T GBIC) Category 5, 5e, 6 UTP SC fiber-optic 1 (1000Base SX/LX/ZX and CWDM GBICs) MMF fiber-optic WS-X6501-10GEX41 port 10- Gigabit Ethernet WS-X6502-10GE with Optical InterfaceStay up-to-date on end of life & end of service life with our simple, easy to use database. 16 port CEF256 Gigabit Ethernet interface module for the Cisco Catalyst 6500 Series switches with single fabric channel interface; requires GBICs; upgradeable to support distributed. Is there any model wgich compine 10 or more of that kind slots ? thanksWS-X6408A-GBIC= Catalyst 6000 8-port GE, Enhanced QoS (Req. 5-4-2. . Hi, You can use the same document which you pointed out in your query. 11ac 802. The 6513, with up to 12 line cards, supports any mix of WS-X6816-GBIC, WS-X6516A-GBIC, WS-X6516-GBIC, WS-X6416-GBIC or WS-X6408A-GBIC. 1 1 2 1000BaseX Supervisor WS-X6K-SUP1A-2GE yes ok 15 1 1 Multilayer Switch Feature WS-F6K-MSFC no ok 3 3 8 1000BaseX Ethernet WS-X6408A-GBIC no ok 4 4 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok 5 5 48 10/100BaseTX Ethernet WS-X6348-RJ-45 no ok 6 6 8 T1 WS-X6608-T1 no ok 7 7 24 FXS WS-X6624-FXS no ok 8 8. 5 (1). 0. GBICs) WS-X6516A-GBIC= Catalyst 6500 16-port GigE Mod, fabric-enabled (Req. WS-X6408A-GBIC to provide port capacity is a good or bad idea in this scenario? I appreciate that using a WS-X6408A-GBIC means that the classic 32Gbps shared bus will be used (with a max of 15Mpps per system) but in raw performance numbers this is a significant increase on the 7206VXR/NPE-G1s1 1 Wireless LAN Service Module WS-SVC-WLAN-1-K9 SAD0805032J 2 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL05073UXR 3 48 48 port 10/100 mb RJ45 WS-X6348-RJ-45 SAD05090C87 6 2 Supervisor Engine 720 (Active) WS-SUP720-BASE SAD0802089E Mod MAC addresses Hw Fw Sw Status. Search Product. OIKWAN Console Cable,USB Console Cable, USB to RJ45 Console Cable with FTDI chip Compatible with. Customers with active service contracts will continue to receive support from the. Dataknox includes support for the Cisco model WS-X6408-GBIC among many others. Chinese; EN US; French; Japanese; Korean; Portuguese320 + 40 = 360. 2 MB shared between 8 ports. The architecture of the WS-X6408A-GBIC allows the Supervisor engine CPU to make forwarding decisions which enhances. 00 Watts (90. . 7 2 ws-x6101-oc12-mmf sad0521049c hw : 1. 3 16 SFM-capable 16 port 10/100/1000mb RJ45 WS-X6516-GE-TX SAL09222DJ4. 1(1d) 4 48 ws-x6348-rj-45 sal05268yuj hw : 3. WS-X6408A-GBIC 8-port Gigabit Ethernet GBIC. 6. 00. Hi I having problems configuring this switch. GS1 Address: 170 West Tasman Drive San Jose US: Description: Cisco Catalyst 6500 series mixed media/fiber-based gigabit Ethernet interface modules are used in distribution and core layers, and in data-center applications. The following modifications were made: • Support was introduced for the following features: – Platform QoS on tunnel interface – Platform ACLs on tunnel interface – Multicast over VTI • Fragmentation behavior was changed. ! interface GigabitEthernet3/3 description QOSTEST ip address. 1 2 Catalyst 6000 supervisor 2 (Active) WS-X6K-S2U-MSFC2 SAL0611141M. I will have a new backbone, running single mode. WS-X6408A-GBIC Catalyst 6000 8-port Gigabit Ethernet, Enhanced QoS (Req. 4 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL06220KEX. I add some specifications of the siwtch. 2(18)SXF7的版本說明。您需 要檢查此IOS是否支援模組WS-X6408A-GBIC。Um chassi 6506 com:WS-X6K-SUP1A-2GE executado no modo híbrido 6. 9 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL05073UXH Mod MAC addresses Hw Fw Sw Status 1 0019. We recently had the sup fail along with the line card. 00 2514 16/8 MEM NEW/OPEN BOX $500. We are planning to add/upgrade one of the GBIC's modules in Cat6509 chassis and I am not sure what would be the best choice and how to select one. QUALITY: ABOUT: CONTACT MFG NSN. 1. Refer to your software release notes to determine if a specific GBIC transceiver or SFP transceiver is supported on your module. Click to View. 1 7. Hi, Our Internet BGP tier is currently provided by a pair of 7206VXR routers with NPE-G1s which are getting quite long in the tooth. Catalyst X6724 switch pdf manual download. GBICs) - WS. Een 6509-chassis met: WS-SUP32-2 GE-3B dat in de native modus 12. China Fiber Transceivers Cisco 8 Port Switch , Ethernet Cisco 8 Port Managed Switch, Find details about China Cisco Network Switch from Fiber Transceivers Cisco 8 Port Switch , Ethernet Cisco 8 Port Managed Switch - Shenzhen HeYiQianChuang Trading Co. 2 Catalyst 6000 supervisor 2 (Cold) WS-X6K-S2U-MSFC2. 12-27-2005 07:15 PM The WS-X6408A-GBIC module offers the same features as those offered in WS-X6408-GBIC. U moet controleren of deze IOS module WS-X6408A-GIBIC ondersteunt. My 6509 will be the core. . Explore our database of over 20,000 parts & never miss a critical date again. WS-X5225R, WS-X6408A-GBIC, WS-X5530-E3A, WS-X5410, WS-X6348-RJ45, WS-X5530-E3, WS-X6148-GE-TX, WS-X6324-100FX-MM, WS-X6416-GBIC, WS-X6748-GE-TX. Mod MAC addresses Hw Fw. . GET REPAIR QUOTE! BUY HARDWARE EQUIPMENT! +91-96328 19991 +91-80-4168 9448 [email protected](33)SXI3 OkSolved: Hi All I have an iusse with bringing up a mwam module into service Mod Ports Card Type Model Serial No. Install 2x WS-X6408A-GBIC that I still have lying around 2. The sup on this router is SUP-720-3BXL. Transceiver Illustration Transceiver Specification Table GBIC † WS-X6408A-GBIC † WS-X6416-GBIC † WS-X6516-GBIC †. Our extended warranty service for this model and others encompasses comprehensive coverage, ensuring seamless operations and minimized downtime. 0 1. Octopart is the world's source for WS-X6408A-GBIC availability, pricing, and technical specs and other electronic parts. Felipe, Are you saying that the SPF ports are not intended to be used for primary connectivity? Mine seem to work perfectly - I've been using them for several years on my SA-6000s. 2(17d)SXB11a. 5(1)でサポートされています。1 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC. users could not connect anymore. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center. Maxsold is a leading estate sale marketplace. SXF11. bin. 00 Get Discount: 15: WS-X4232-GB-RJ-RF. ws-x6408a-gbic; ws-x6416-gbic; ws-x6516a-gbic および ws-x6516-gbic; ws-x6724-sfp および ws-x6824-sfp; ws-x6748-sfp および ws-x6848-sfp; ws-x6816-gbic; 10 ギガビット イーサネット モジュール. Vibrant Technologies offers the Cisco WS-X6408A-GBIC for sale, a Modules option and we buy and sell new and used Networking equipment and parts at deep price discounts off the Cisco list pricing. > Modules > Cisco WS-X6408A-GBIC 8 port Gigabit Expansion module. With releases earlier than Release 12. 4 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B 7 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC 8 8 8 port 1000mb ethernet WS-X6408-GBIC 9 48 48 port 10/100 mb RJ45 WS-X6348-RJ-45 Mod Sub-Module Model Serial Hw Status. GBICs) — Product Migration Options Customers are encouraged to migrate to the 16-port CEF256 Gigabit Ethernet interface module for the Cisco Catalyst 6500 Series Switches (product number WS. . show module switch # slot #. bin. Intenta quitar todos los modulos e ir instalando uno por uno y o probar los modulos en diferentes slots para ir descartando fallas. Page 1 This document will attempt to provide a high level overview of the QoS features found on the Cisco Catalyst 6500. Cat6500 16pt GigE Mod. Any help to understand why it is giving that message and the solution to overcome the same would be really appreciated. I have an issue with one of my Gig-E interface's on my 7609. 3. 1. com WorldwideWS-G5483: Cisco 1000BASE-T GBIC: WS-G5484: Cisco 1000BASE-SX Short Wavelength GBIC (Multimode Only) WS-G5486: Cisco 1000BASE-LX/LM Long-Haul GBIC (Single Or Multimode) WS-G5487: Cisco 1000 BASE-ZX Extended Reach GBIC (Singlemode) WS-G6483: Catalyst 6500 10GBASE-ER Serial 1550nm Extended Reach OIM (SMF) X2. WS-SUP720-3BXL . 80 OR Qty Add to Cart Qty Add to Cart Looking for a large quantity of WS-X6408A-GBIC? Call us at (855) 483-7810 or Request a Bulk Quote and our sales representative. WS-X6408A-GBIC= Catalyst 6000 8-port GE, Enhanced QoS (Req. 6 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL0536B5AY 7 48 48-port 10/100/1000 RJ45 EtherModule WS-X6148A-GE-45AF SAL1415FG8R 8 48 48-port 10/100/1000 RJ45 EtherModule WS-X6148A-GE-45AF SAL1415F6GJ 9 48 48-port 10/100/1000 RJ45 EtherModule WS-X6148A-GE-45AF SAL1415F6K5. This night we had a problem with a WS-X6408A-GBIC module in our Cat6k chassis,the module resetted from itself without any reason. Menu. Edison Ortiz. Hello, Forgive me for the basic nature of my questions and for the length of this message. fabric-enabled REMANUFACTURED. 9 9 8 1000BaseX Ethernet WS-X6408A-GBIC no ok After sup2: CAT_1> (enable) sh mod Mod Slot Ports Module-Type Model Sub. . 99. Not all GBIC transceiver types or SFP transceiver types may be supported on your module. Cisco WS-X6380-NAM Catalyst 6000 Network Analysis Module. Although the module in second slot is removed in the C6509 , the configuration of the module doesn't disappear on the configuration when I enter show running-config. Regards. End-of-Life Milestones and Dates for Cisco Catalyst 3550 Series Switches Milestone Definition Date End-of-Life Announcement Date. GBICs) WS-X6516A-GBIC= Catalyst 6500 16-port GigE Mod, fabric-enabled (Req. Hi, I have a 6506 with SUP1 MSFC2, running IOS. We are selling these Cisco WS-X6408A-GBIC cards for $2950. USD 297. 5 MSFC3 Daughterboard WS-SUP720 SAL1225UPWN 3. fw : 4b4lz0xa. 1. Contact & Return; Returns and Exchanges; Blog; Call 313-251-4434 || Mon-Fri 10am-5pm EST이 섹션에서는 Cisco IOS 소프트웨어를 실행하는 Catalyst 6500/6000에서 출력 예약을 구성하는 데 필요한 모든 단계를 설명합니다. Buy or Renew. 2 visitors have checked in at W&S Bookkeeping Service. 4 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B 7 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC 8 8 8 port 1000mb ethernet WS-X6408-GBIC 9 48 48 port 10/100 mb RJ45 WS-X6348-RJ-45 Mod Sub-Module Model Serial Hw Status. Using CEF you will get up to 30 Mpps per system, or you can install the dCEF upgrade to support 48 Mpps. > > 1. Catalyst 6500. Cisco Catalyst 6500 Series10/100 and 10/100/1000 modules are the key enablers of a Borderless Network access solution. WS-X6516A-GIBIC. 1. 0(11b)WS-X6408A-GBIC Chassis 6509 con:WS-SUP32-GE-3B in esecuzione in modalità nativa 12. Fw : 5. Just follow the document checklist and steps: The module on which the above gig interface is WS-X6408A-GBIC and the IOS version running on this router is s72033-advipservicesk9_wan-mz. USD 39. WS-X6408-GBIC WS-X6408A-GBIC WS-X6416-GBIC WS-X6516-GBIC WS-X6516A-GBIC WS-X6816-GBIC8 or 16 GBIC module slots RJ-45 (for 1000Base-T GBIC) Category 5, 5e, 6 UTP SC fiber-optic 1 (1000Base SX/LX/ZX and CWDM GBICs) MMF fiber-optic WS-X6501-10GEX41 port 10- Gigabit Ethernet WS-X6502-10GE with Optical InterfaceStay up-to-date on end of life & end of service life with our simple, easy to use database. GBICs) WS-X6516A-GBIC= Catalyst 6500 16-port GigE Mod, fabric-enabled (Req. Cisco announces the end-of-sale and end-of life dates for the Select Cisco Catalyst 6500 Series Line Cards and Power over Ethernet (PoE) Daughter Cards. Catalyst 6500 24. 9df6. 3(1) DRAM FLASH NVRAM. GBICs REFURBISHED. the 6408A, was announced for end-of-sale in 2009, and will go end-of-life in 2014. Hi all, I have a couple of questions regarding the above switch and hope I can get some answers with your help. 4(2) Sw : 7. Add to Wishlist. We sell Cisco WS-X6408A-GBIC Catalyst 6000 8-Port Gigabit Ethernet Switching Module at great prices and offer a full warranty on the Cisco products we sell. The WS-X6408A-GBIC module has enhanced QoS features. Buffer Size of 1M per port. 2 (18)SXD, WS-CAC-6000W is limited to 4,000 W in WS-C6509-E. Refer to your software release notes to determine if a specific GBIC transceiver or SFP transceiver is supported on your module. Three fields on the Catalyst 6500/6000 are used to make QoS: The IP precedence—The first three bits of the Type of Service (ToS) field in the IP header. NSN > NSN. EN US. Action taken:. GBICs) — Product Migration Options Customers are encouraged to migrate to the 16-port CEF256 Gigabit Ethernet interface module for the Cisco Catalyst 6500 Series Switches (product number WS. January 31, 2012 . Securely connecting to anyone, anywhere, using any device. " We've also had the module in slot 5 fail twice with the same symptoms. in Germany: +49 89 20190324. 1. Cisco Catalyst 6500 Series 8-port Classic Gigabit Ethernet interface module with enhanced QoS, 2 x 30-0703-01, 4 x 30-0759-01 Part Number-WS-X6408A-GBIC This is fully tested, used item in good, working condition with cosmetic signs of use, marks on the casing and on the edges. In which slot should I insert WAN module in Cat 6509-E? I could not find any relevant document on it. Do youPRODUCT BULLETIN - CONFIDENTIAL, NO. SXF11. . Mod Ports Card Type Model Serial No. 4 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B 7 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC 8 8 8 port 1000mb ethernet WS-X6408-GBIC 9 48 48 port 10/100 mb RJ45 WS-X6348-RJ-45 Mod Sub-Module Model Serial Hw Status. I need to buy the DFC3BXL in this case. I would like to inquire if WS-X6408A-GBIC 8 port 1000mb GBIC supports single mode, I am currenlty using it for mulit-mode backbone and patch cord. Do I need to upgrade the cisco CAT OS version. GBICs) — Product Migration Options Customers are encouraged to migrate to the 16-port CEF256 Gigabit Ethernet interface module for the Cisco Catalyst 6500 Series Switches (product number WS-X6516A-GBIC). 00 Add to cart; WS-X6848-TX-2T Read more; WS-X6748-SFP4 4 8 1000BaseX Ethernet WS-X6408A-GBIC no ok. suggest so can be made UP & Functioning. cisco. 1. WS-X6408A-GBIC-RF. Fw : 5. 4(2) sw : 8. --- ----- ----- ----- ----- 1 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC View and Download Cisco Catalyst X6724 datasheet online. 7 48 48 port 10/100 mb RJ-45 ethernet WS-X6248-RJ-45 SAD041509N5 WS-X6408A-GBIC; WS-X6416-GBIC; WS-X6516-GBIC; WS-X6516A-GBIC; WS-X6816-GBIC; Figure A-10. Cat6500 16pt GigE Mod. 2(18)SXF7. Never miss a Cisco EOL or EOSL date again. Bias-Free Language. Hi, I have a 6506 with SUP1 MSFC2, running IOS. 67 and then a few minutes later it jumps to 107875360. 3 8. Hi, &nbsp; I am playing with 5224 and two Cisco switches - 3509G and 7606. WS-X6816-GBIC . 5 (1). 1. VS-S720-10G-3C. 1000BaseS X/LX/ZX y CWDM) MMF WS-X6501-10GEX4 1 puerto 10-Gigabit Ethernet WS-X6502-10GE con módulo de interfaz ópticaFind accurate end of life & end of service life dates for Cisco WS-X6408A-GBIC hardware. Module Total Used Free Total Used Free Total Used Free. 3(2) 5 8 WS-X6408A-GBIC SAL06240XWX Hw : 2. 3(1) DRAM FLASH NVRAM. Buy or Renew. 4(2) sw : 8. The last day to order the affected product(s) is January 30, 2008. Hi I having problems configuring this switch. fw : 5. Both sides of the trunk are set at nonnegotiate ISL. GBICs) WS-X6516A-GBIC= Catalyst 6500 16-port GigE Mod, fabric-enabled (Req. GBICs) WS-X6516A-GBIC Catalyst 6500 16-port GigE Mod, fabric-enabled (Req. WS-CAC-2500W Catalyst 6000 2500W AC Power Supply. 3560 has GLC-LH-SM LX/LH tranceiver. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. :. cheers~ fawadWS-X6408A-GBIC 2-67 to 2-69 WS-X6416-GBIC 2-70 to 2-72 WS-X6516A-GBIC 2-73 to 2-77 WS-X6516-GBIC 2-73 to 2-77 WS-X6724-SFP 2-78 to 2-83 WS-X6748-SFP 2-83 to 2-89 WS-X6816-GBIC 2-89 to 2-92 WS-X6824-SFP-2T/-2TXL 2-78 to 2-83 WS-X6848-SFP-2T/-2TXL 2-83 to 2-89 1-GB transceivers See either GBIC transceivers or SFP transceivers. 4(19) + MSFC 12. The supV also supports a WS-X4302-GB in slot 10. 6 48 48-port 10/100/1000 RJ45 EtherModule WS-X6148A-GE-TX SAL09422XQ4We discovered a strange problem when we upgraded from WS-X4013 (sup 2's) to WS-X4013+ (sup 2+'s) on our 4506's. Page 15 Cisco Catalyst 6500 48-port fabric- enabled 10/100/1000 module WS-X6816-GBIC Cisco Catalyst 6500 16-port GigE mod: fabric-enabled (req. We suspect the issue is related to using the Sup1A as a VMPS server for the LAN, as the memory leak has worsened as the size of our vmps. The mustI got two options. 185 KB shared between 8 ports. What is the NAM module should we go for ?. 1(4)E3. ThBuy or Renew. 1(4)E3. 4(2) sw : 8. 001 2 Catalyst 6000 supervisor 2 (Active) WS-X6K-SUP2-2GE SAL08154S4S. 부품 번호:WS-X3500-XL(GigaStack GBIC. Moreover I need to add a 100Mbit/s fiber module (it's for Internet Connectivity), is there any way to set it up ? For the Gbic, I will use WS-G5484, which doesn't seem to accep. 38 Watts could cover demand: 991. Cisco PA-8T-V35 Module for 7204VXR 7206VXR. However when they are co. 2(18)SXF7에서 실행되는 WS-SUP32-GE-3BWS-X6516A-GIBIC 이 예에서는 두 GBIC 모듈을 모두 교체합니다. Module 1: WS-X6K-SUP1A-2GE Module 2: Removed Module 3: WS-X6348 Module 4: WS-X6348 Module 5: WS-X6408A-GBIC Module 6: WS-X6408A-GBIC However, its not able to detect the switch module. ! class-map match-any <name>. Find accurate end of life & end of service life dates for Cisco WS-X6408A-GBIC hardware. 1. Cisco PA-2T3 Module. 7-3-1. 2 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC 4 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B 8 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX. The current configuration we have is this: WS-X6K-SUP1A-2GE WS-X6. WS-X6516-GBIC The 8-port Gigabit Ethernet switching module (WS-X6408A-GBIC) provides eight switched, full-duplex Gigabit Ethernet ports that you can configure with any combination of 1000BASE-SX, LX/LH, and ZX GBICs, copper GBICs, or Coarse Wave Division Multiplexer (CWDM) GBICs. Re:looking for a Fiber optic switch. GBICs) WS-X6516A-GBIC Catalyst 6500 16-port GigE Mod, fabric-enabled (Req. Cisco Catalyst WS-C2960X-24PD-L 24 Port Ethernet Switch with 370 Watt PoE; Cisco CISCO2951/K9 Router; Used Cisco Switches vs. End-of-Life Announcement Date . e829. Will this NAM module do the same jobI want to create multiples Vlans with this switch. The 6408 has been end-of-life for about five years. Description. Hi, Our Internet BGP tier is currently provided by a pair of 7206VXR routers with NPE-G1s which are getting quite long in the tooth. These gig ports default to auto-negotiate, and mine are left that w. This is how the configuration looks: 6506 with Supervisor Engine 1 <= WS-X6516A-GIBIC 6509 with Supervisor Engine 32 <= WS-X6408A-GIBICSolved: Hello, I have a WS-C6509 chassis with the following modules: 2x WS-X6K-SUP1A-2GE; 3x WS-X6408A-GBIC; 1x WS-X6516A-GBIC; 1x WS-X6348-RJ-45 and WS-X6148-GE-TX. xではサポートされていません。ws-x6516a-gbicバージョンは、ソフトウェアリリース7. GBICs) WS-X6516A-GBIC . Buy or Renew. 62 Watts < 1171. &nbsp; 5224 over GBiC SX negotiates fine with 3509G but I cannot force 5224 to work with 7606. GBICs) — Product Migration Options Customers are encouraged to migrate to the 16-port CEF256 Gigabit Ethernet interface module for the Cisco Catalyst 6500 Series Switches (product number WS. Sample logging. by e-Mail: office@hardwarewartung. VS-S720-10G-3C. 2 48 48-port 10/100/1000 RJ45 EtherModule WS-X6148A-GE-TX. 88MB. 1(1d) 5 2 ws-x6380-nam sad052500wl hw : 1. USD 297. 2. I would like to get some information about how I can configure Vlans over ISL or IEEE. Log In. When I start session 15 in enable mode I only get Vlan 1 when I use the show interface command. In this example, both GBIC modules will be swapped. 4. Vista Bay Road, Victoria, BC, V8P 3G1. 1(1a) sw1: 6. Request Bulk Quote. IT Hardware Maintenance. Vervolgens moet je bekijken welke toezichthouders module WS-X6408A-GIBIC ondersteunen. . Never miss a Cisco EOL or EOSL date again. 1P2Q2T shared between 8 ports. If you need any hint just ask me and I will be more specific. Y . Moreover I need to add a 100Mbit/s fiber module (it's for Internet Connectivity), is there any way to set it up ? For the Gbic, I will use WS-G5484, which doesn't seem to accep. GBICs) — Product Migration Options Customers are encouraged to migrate to the 16-port CEF256 Gigabit Ethernet interface module for the Cisco Catalyst 6500 Series Switches (product number WS-X6516A-GBIC). Could this be a hardware issue? Router#show module Mod Ports Ca. The thinking was that without the power reservation, I would be able to run redundant mode without losing any line cards because: 1306. Table B-1 lists the types of 100-MB SFP. GBICs REFURBISHED. Regards. MDF#sh run int g9/20. Module Total Used Free Total Used Free Total Used Free. Every once in a while my input rate counter will show -93420686. 606. Buy or Renew. Install 2x WS-X6408A-GBIC that I still have lying around 2. Catalyst 6500 16-port GigE Mod, fabric-enabled (Req. Hall of Fame In. hey folks I am planing to upgrade one of our core switch running CATOS to accomodate WiSM on sup-engine WS-X6K-SUP1A-2GE with following service modules as follows Mod Slot Ports Module-Type Model Sub Status --- ---- ----- -----Catalyst 6500 bits and pieces. 2(18)SXD7b and want to upgrade to the version 122-33. We have 3 providers, 2 are 100mbs links, 1 is gigabit link. 100-MB small form-factor pluggable (SFP) transceivers are currently the only 100-MB transceivers that are supported on a Catalyst 6500 series Ethernet switching module. 29. Refer to your software release notes to determine if a specific GBIC transceiver or SFP transceiver is supported on your module. Chinese; EN USWe have cisco 6509 with the following configuration System Bootstrap Version: 7. 5(1)でサポートされています。1 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC. 6 48 unknown FRU type (major = 0x6003, mino WS-X6548-GE-TX SALXXXXXXXXWS-C6509 Cat 6509 Chassis, 9slot, 15RU, No Pow Supply, No Fan Tray. MDF#sh run int g9/20. Gigabit ethernet modules (6 pages). Customers with active service contracts will continue to receive support from. It will explain what the features are, how they work, and where in hardware they are performed. Fw : 12. IT Hardware Maintenance. Instock and fully tested, Same Day ShippingNeed to know CISCO CATALYST 6000 8-PORT GE ENHANCED GBIC EOL & EOSL Date? CISCO CATALYST 6000 8-PORT GE ENHANCED GBIC EOL Date Not. 2 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX SAL1006D4V0 5 5 Supervisor Engine 720 10GE (Hot) VS-S720-10G SAL1514AF3S 7 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL10499QH0 8 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL1052C3L0If you have any Refurbish,Used or End of life surplus that you wish to sell, feel free to forward us your list or to contact us! We'll get you the best value out of. WS-X6248A-TEL. WS-X6516A-GBIC CEF256 16, GBIC Tx-1p2q2t Rx-1p1q4t WRR 1 MB Base Server Farm WS-X6516-GBIC* CEF256 16, GBIC Tx-1p2q2t Rx-1p1q4t WRR 512 KB Base Server Farm WS-X6416-GBIC Classic 16, GBIC Tx-1p2q2t Rx-1p1q4t WRR 512 KB Base Server Farm WS-X6408A-GBIC Classic 8, GBIC Tx-1p2q2t Rx-1p1q4t WRR 512 KB Cisco announces the end-of-sale and end-of life dates for the Select Cisco Catalyst 4500 Non-E-Series Supervisor Engines. 8MB. 6(4) and the mfsc are running 12. 3(2) 5 8 ws-x6408a-gbic sal06240xwx hw : 2. 2(33)SXH With Supervisor Engine 720. . I add some specifications of the siwtch. 2 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL06386ADM 3 8 CEF720 8 port 10GE with DFC WS-X6708-10GE SAL11381CWN 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAD0851092G. Can you help, I have 6509's configured with Sup1a, running CatOS 7 with the following cards, WS-X6K-SUP1A-2GE WS-F6K-PFC WS-X6408A-GBIC WS-X6348-RJ-45 WS-SVC-NAM-1 I am a little confused which Supervisor and. Chinese; EN US; French; Japanese; Korean; Portuguese; Log InSUP: 2 x [WS-SUP720-3B + WS-SUP720 MSFC3 Daughterboard + WS-F6K-PFC3B Policy Feature Card 3] 10G LC: 2 x [WS-X6704-10GE + WS-F6700-CFC] 1G LC: 1 x WS-X6408A-GBIC + 1 x WS-X6516A-GBIC. 1 1 2 1000BaseX Supervisor WS-X6K-S2U-MSFC2 yes ok 15 1 1 Multilayer Switch Feature WS-F6K-MSFC2 no ok 3 3 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok. Repair/Replacement Warranty. The module is a WS-X6408A-GBIC. NETGEAR 26-Port PoE Gigabit Ethernet Smart Switch (GS324TP) - Managed, with 24 x PoE+ @ 190W, 2 x 1G SFP, Desktop or Rackmount, S350 series. (11b)WS-X6408A-GBIC 다음을 포함하는 6509 섀시기본 모드 12. Two WS-X6408A-GBIC modules 3. R/O WDM GBIC. 62 Watts, a single power supply of 1171. 62 Watts - 315 Watts = 991. Mod MAC addresses Hw Fw Sw Status 3 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL0617320V Mod MAC addresses Hw Fw Sw Status 1 0016. and with a total requirement of 991. 4 48 48-port 10/100 mb RJ45 WS-X6148-RJ-45 SALXXXXXXXX. . Hello Guys, Below is the snap shot for my 6500 switch modules which is showing that WS-SVC-IDSM-2 card on slot 7 and WS-SVC-WISM-1-K9 card on slot 9 is down and status is not ok, Pls. Solved: Hi, We have WS-X6348-RJ-45, WS-X6324-100FX-MM, WS-X6408A-GBIC and WS-X6816-GBIC ( with daughter card WS-F6K-DFC ).